| Scope of protection of the
PRCD-S: |
 |
In the event of a fault in the connected electrical
equipment, protection in accordance with DIN VDE 0661. |
 |
Fault currents caused by defective consumers lead to all-pole
cut-out by the PRCD-S. |
| |
|
 |
In the event of system errors in the stationary installation,
the PRCD-S dtetects all possible faults in the stationary installation
and cannot then be switched on. |
| |
|
 |
In the event of drilling into external lines, full protection
is provided through SL safety measures in the external line. |
 |
The PRCD-S detects the external voltage on the PE - but does
not interrupt the PE connection. |
 |
The external voltage can thus be cleared by its own series
connected safety organs RCD and MCB. |
| Use and function |
 |
Specially for building sites and the fire brigade,
in accordance
with the recommendations of the employer's liability insurance
association for precision and electrical engineering, and suitable
for all mobile electrical equipment. |
 |
encapsulated design for harsh conditions |
 |
suitable for direct connection in the electrical device feeder
(H07 RN-F 3G2,5mm²) |
 |
can be used independent of the plug system in use |
 |
large, easy to operate ON and OFF buttons |
 |
additional, optical switch position display |
 |
low voltage release |
 |
extremely short trigger time (<30ms) |
 |
IP 55 splash-proof |